PWM charge controller doesn't have a fixed max. PV power limit. But the Voc of the PV array needs to be lower than the max. Voc of the controller and the Isc of PV array need to be lower than the rated charge current of controller.
With RS485 interface and optional remote meter.
LandStar-B series is a common positive PWM charge controller. Thanks to the RS485 interface. The parameters can be configured via com. Port, APP, and PC software. It is widely applied to solar home systems, and surveillance system, etc.,
Model | LS1024B | LS2024B | LS3024B |
Nominal system voltage | 12/24VDC/Auto | ||
Battery type | Sealed(Default)/Gel/Flooded/User | ||
Battery input voltage range | 8~32V | ||
Rated charge current | 10A | 20A | 30A |
Rated discharge current | 10A | 20A | 30A |
Max. PV open circuit voltage | 50V | ||
Equalization voltage | Sealed:14.6V,Flooded:14.8V,User-defined:9-17V | ||
Boost voltage | Gel:14.2V,Sealed:14.4V,Flooded:14.6V,User-defined:9-17V | ||
Float voltage | Gel/Sealed/Flooded:13.8V,User-defined:9-17V | ||
Low voltage reconnect voltage | Gel/Sealed/Flooded:12.6V,User-defined:9-17V | ||
Low voltage disconnect voltage | Gel/Sealed/Flooded:11.1V,User-defined:9-17V | ||
Self-consumption | ≤8.4mA/12V;≤7.8mA/24V | ||
Temperature compensation | -3mV/℃/2V (default) | ||
Relative humidity | ≤95% (N.C.) | ||
Enclosure | IP30 | ||
Communication interface | RS485(RJ45) | ||
Grounding | Common Positive | ||
Operating temperature range | -35℃~50℃ | ||
Dimensions(LxWxH)(mm) | 138.6×69.3×37 | 159.6×81.4×47.8 | 200.6×101.3×57 |
Net Weight | 0.13kg | 0.30kg | 0.50kg |
EPEVER-Datasheet-LS-B
LS-B-SMS-EL-V2.5
Certificate EMC LandStar-B
Certificate IEC62109 LandStar-B
Certificate ROHS LandStar-B
Product Highlights
Series PWM charging Mode
Multiple load control modes
Full load operation within the working temperature range
Extensive electronic protection
Variety optional accessories
Standard Modbus communication protocol with RS485 interface
PWM charge controller doesn't have a fixed max. PV power limit. But the Voc of the PV array needs to be lower than the max. Voc of the controller and the Isc of PV array need to be lower than the rated charge current of controller.
EPEVER Admin 13 July 2021
Cookie | Duration | Description |
---|---|---|
cookielawinfo-checkbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
cookielawinfo-checkbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |
Reviews
There are no reviews yet.