Products

RC11 (2.4G RF remoter), FC02 (2.4G RF keychain remoter), eBox-WiFi&2.4G-02 (WiFi to 2.4G converter)

13 July 2021

What are the accessories?

RC11 (2.4G RF remoter), FC02 (2.4G RF keychain remoter), eBox-WiFi&2.4G-02 (WiFi to 2.4G converter)
13 July 2021

What is the advantage of 2.4G communication comparing with IR?

2.4G communication has stronger signal penetration (through plastic/aluminum housing). The communication can reach 20m.
13 July 2021

How to choose the controller according to the LED lamp?

① Make sure the LED street lights do not have a built-in LED driver. ② Make sure the rated output voltage of the charger is higher […]
13 July 2021

The default baud rate of the controller is 115200bps. Can I change it to 9600bps?

It is not recommended to change the baud rate. Changing the baud rate may cause a communication failure.
13 July 2021

What is the Max. PV power of the charger?

PWM charge controller doesn't have a fixed max. PV power limit. But the Voc of the PV array needs to be lower than the max. Voc […]
13 July 2021

How to set the Load working mode and control parameters?

The voltage setpoints are fixed. The load working mode can be set via the button and LED tube on the unit.
13 July 2021

How does "Test mode" work?

When LS-EPD is in "Test Mode", the load output will be turned ON immediately when PV is lower than 5V (5V for 12V system, x2 for […]
13 July 2021

What is the rated current of the USB output? Would it be damaged if overloaded?

5V/2A for LS3024EU, 5V/1.2A for other models. If overloaded, there will be over-current protection or even damage to the controller.
13 July 2021

What are the load working mode options?

LS-E(EU)series supports "Manual mode" only (default is ON when power-up). The load will be turned ON and OFF manually.
13 July 2021

What is the Max. output voltage and current on Load terminal?

The load voltage follows the battery voltage and the Max. the load current is 60A (resistive load)
13 July 2021

What is the purpose of the button cell? Is it mandatory?

IT6415ND charge controller has the function of recording the running states and events, but these records would be lost when the unit is powered off if […]
13 July 2021

What is 'External Switch Port' used for and how to use it?

It is used to turn on/off the inverter remotely,e.g., a wall switch. It is paralleled with the ON/OFF switch on the inverter. So the local ON/OFF […]
13 July 2021

Can all parameters be set on the LCD and buttons?

Yes, all parameters can be set via the LCD and buttons on the inverter.
13 July 2021

Does IP-Plus support Li(NiCoMn)O2 battery?

No. The Ipower-plus supports a LiFePO4 lithium battery. It is not compatible with Li(NiCoMn)O2. Because the battery voltage range is too low to work with the […]
13 July 2021

Can output voltage and frequency be set while the unit is powered on?

It is forbidden. Make sure the inverter is off before setting the DIP switches for output voltage and frequency
13 July 2021

Does it come with input polarity reverse protection?

IP series has no input polarity reverse protection. Never connect the battery positive(+) and negative(-) reversely, or the fuse will be burnt and even inverter damaged.
13 July 2021

Do I need to connect external voltge sensor to the controller if voltage sampling is need?

No external voltage sensor is needed, The GM3024N has a built-in sensor, just connect the "BATT remote" port of the charger and the battery with wires.
13 July 2021

Why is remote voltage sampling needed?

The battery voltage on the battery and charger are almost the same, but if the cable is long or the battery current is large, the difference […]
13 July 2021

What is purpose of remote voltage sampling?

To get a more precise battery voltage and control the charging of the battery more accurately.
13 July 2021

Where can GoMate be installed?

GM3024N is a flush-mounted design. It is suitable for wall mount installation in RV, boats, etc.
13 July 2021

What does 'H' mean on the LED dispaly?

"H" means high-temperature alarm. The ventilation conditions for the charger need to be improved if the LED shows"H".
13 July 2021

Can EPIPDB-COM connect with WiFi or Bluetooth modules?

No. The communication port of EPIP-DB can work with MT-1 only.
13 July 2021

What battery type does EPIPDB-COM support? Can it connect one battery bank only?

EPIP-DB supports a Lead-acid battery(Sealed/GEL/FLD). It can work with only one battery bank also.
13 July 2021

Can two batteries have different rated voltage and battery type?

Bat1 and Bat 2 can be different types. But both batteries should have the same rated voltage, i.e., both are 12V batteries or 24V batteries.
13 July 2021

Do both Bat1 and Bat2 support lithium battery?

Bat1 can be a lead-acid battery and lithium battery, and Bat2 has to be the lead-acid battery.
13 July 2021

Does it matter to connect Bat1 first or Bat2 first?

It doesn't matter if both are 12V batteries. If both are 24V batteries, it is required to connect the Bat2 first and the Rated Voltage Level […]